Applications
Bathhouses Pools and Hot Springs
주소복사

◆  Public Baths and Swimming Pools  ◆ 

 


Target Heat Contribution: 70% Wastewater Heat Recovery + 30% Heat Pump

Integrated Hot Water, Heating and Cooling Designed to Replace Boilers

 

ZERO BOILER is an integrated energy system that recovers available waste heat first and uses a heat pump to supply the remaining heat required.

Conventional public baths often discharge warm bathwater and wastewater without fully recovering their heat, while boilers heat the incoming fresh water.

ZERO BOILER uses a counterflow heat recovery system designed to process the full wastewater flow. Recovered heat preheats incoming fresh water, and a heat pump supplies the remaining heating demand to reduce or replace boiler use.


1. Full-Flow Counterflow Wastewater Heat Recovery

Warm wastewater and incoming fresh water pass through separate flow paths in a counterflow heat exchanger, transferring heat without mixing the water streams.

      • Wastewater heat recovery : Target contribution of approximately 70% of the required domestic hot water heating energy.

      • Heat pump : Supplies the remaining approximately 30%.

 

Key functions include :

      • Preheating winter mains water from 5°C to approximately 30°C under the stated operating conditions.

      • Reducing hot water energy consumption by recovering heat from wastewater.

      • Storing preheated water in an intermediate-temperature tank to help meet demand during bath refilling.

 

The core principle is to recover available heat before using additional energy to heat fresh water.


2. Groundwater Supply — Water Source Heat Pump

Facilities using groundwater can use a water source heat pump to take advantage of its relatively stable temperature.

Wastewater heat recovery preheats the incoming water, while the heat pump produces the hot water required for baths and facility heating.

The heat source system is designed according to groundwater temperature, available flow and site conditions.


3. Mains Water Supply — Air Source Heat Pump

Facilities using mains water can also use full-flow counterflow wastewater heat recovery.

Incoming fresh water is preheated using wastewater heat. An air source heat pump then supplies the remaining heat required for hot water and space heating.

This converts a boiler-dependent hot water system into a system centered on waste heat recovery.


4. Summer Cooling Heat Recovery

In summer, heat removed from indoor spaces is recovered for hot water production.

Conventional cooling systems release this heat outdoors. ZERO BOILER is designed to use it for hot water first.

      • Uses heat rejected during cooling for hot water production.

      • Minimizes additional hot water heating within the available heat recovery capacity.

      • Releases excess heat outdoors after hot water demand has been met.

      • Improves summer energy utilization by integrating cooling and hot water production.

While recovered cooling heat meets the hot water demand, the need for additional hot water heating can be minimized.

The compressor and circulation pumps still consume electricity. If hot water demand exceeds the available recovered heat, additional heat pump output or another heat source is required.


5. Integrated System Designed to Replace Boilers

Wastewater heat recovery, heat pumps, intermediate-temperature water storage, and heating and cooling are integrated to reduce facility energy consumption.

 

ZERO BOILER — Recover available heat first. Supply only the remaining heat required.

 

The 70% heat recovery and 30% heat pump figures are design targets for hot water heating energy. Actual contributions depend on fresh water and wastewater temperatures, available wastewater flow, operating conditions and heat exchanger performance.

 

Whether supplied by mains water or groundwater, ZERO BOILER starts with the heat that would otherwise be wasted.

 

         ◆  상수도 / 계통도  ◆   

 Winter Operation

  • Uses an air source heat pump in a public bath supplied with mains water.

  • Recovers wastewater heat through a plate heat exchanger to preheat incoming fresh water.

  • Uses separate hot water and space heating storage tanks to supply domestic hot water and FCU heating.

  • Preheats winter mains water from 5°C to approximately 30°C under the stated operating conditions.

  • At a final water temperature of 36°C, this preheating represents approximately 80% of the required water heating energy.

  • The heat pump supplies the remaining approximately 20% of hot water heating energy, together with the required space heating energy.

Recover available heat first, then use the heat pump to supply the balance.

  

 Summer Operation

  • Wastewater heat recovery preheats incoming fresh water.

  • The heat pump recovers heat removed during cooling and uses it to produce hot water.

  • Chilled water passes through the cooling storage tank and is supplied to FCUs.

  • Hot water is stored in the domestic hot water tank and supplied to the bathing facilities.

  • Recovered heat that is not needed for hot water is released outdoors.

  • Heat recovery and outdoor heat rejection are controlled according to cooling load and hot water demand.

Use cooling heat for hot water first. Release only the excess heat outdoors.

      ◆  Groundwater System Diagram  ◆

 

Groundwater Heat Utilization — ZERO BOILER

Groundwater at approximately 17°C provides heat for hot water production. The cooled water is then used for cold baths and, through a separate heat exchange circuit, FCU cooling.

Heat recovered from discharged wastewater preheats incoming groundwater, reducing the additional heat required for hot water supply.

Medium-temperature water storage helps meet peak demand when baths are drained and refilled, while a separate hot water tank supplies higher-temperature water.

By integrating groundwater heat, wastewater heat recovery and thermal storage, the system provides hot water, cooling and heating, enabling boiler replacement where site conditions allow.

 

 

 

Public Bath Hot Water and Heating System

  1. Uses groundwater as a stable heat source, supporting boiler replacement.

  2. Recovers wastewater heat through a plate heat exchanger.

  3. Stores medium-temperature water to meet peak demand when baths are drained and refilled.

  4. Produces water at approximately 40°C for bath filling.

  5. Provides summer cooling and winter heating through fan coil units (FCUs).

  6. Enables boiler-free operation when sized to meet the facility’s heating and hot water loads.


 
 

◆  Hot Springs and Water Parks  ◆ 

 

 

Hot springs and water parks continuously use large volumes of water and require substantial energy to maintain bath and pool temperatures.

ZERO BOILER recovers heat from available hot spring water or warm discharge water and can be integrated with water source or air source heat pumps.

Combining bath and pool temperature control, shower hot water, space heating, dehumidification and cooling allows energy flows to be managed as one system.

For large facilities, multiple heat pumps can be installed in parallel and operated in stages according to demand.


Facilities with large, recoverable flows of warm water offer significant opportunities for heat recovery and integrated operation.


         ◆  System Diagram  ◆   

ZERO BOILER for Hot Springs and Water Parks

  • Integrates wastewater heat recovery, heat pumps and intermediate-temperature water storage.

  • Uses groundwater as a heat source for hot water production where suitable groundwater is available.

  • Uses recovered cooling heat for hot water production and bath or pool temperature maintenance.

  • Recovers heat when baths are drained to preheat fresh replacement water.

  • Stores preheated water in the intermediate-temperature tank.

  • Maintains the intermediate-temperature water at approximately 40°C for bath refilling and temperature maintenance, according to facility requirements.

  • Uses recovered heat first, with heat pumps supplying the remaining demand to support boiler-free operation.

Transfer heat from discharged bathwater to fresh replacement water, then reuse it for hot water supply and temperature maintenance.


Intermediate-Temperature Water Storage — Patent Application Filed

  1. Heat from bathwater discharged during cleaning is recovered and transferred to fresh water stored in the intermediate-temperature tank.

  2. The heat pump maintains the stored water at approximately 40°C.

  3. Water at approximately 40°C is supplied directly to individual baths.

  4. The proposed configuration supplies water at the required temperature without a mixing valve.

  5. Air source heat pumps are used for mains-water configurations, while water source heat pumps are used for suitable groundwater configurations.


 ◆  설치 사례  ◆ 


 
 
 ​ ​ ​​